• Iodometry, known as iodometric titration, is a method of volumetric chemical analysis, a redox titration where the appearance or disappearance of elementary...
    9 KB (1,149 words) - 10:54, 10 May 2024
  • Thumbnail for Iodine–starch test
    interaction between starch and the triiodide anion (I− 3) is the basis for iodometry. The iodine–starch test was first described in 1814 by Jean-Jacques Colin...
    12 KB (1,287 words) - 02:10, 12 September 2024
  • Thumbnail for Sodium thiosulfate
    Na2S2O3·5H2O has an excellent shelf-life, it is used as a titrant in iodometry. Na2S2O3·5H2O is also a component of iodine clock experiments. This particular...
    14 KB (1,293 words) - 06:37, 8 September 2024
  • Proceedings of the Indian National Science Academy. 46 (6). Indian National Science Academy: 562–564. ISSN 0370-0046. Retrieved 2009-03-20. Iodometry v t e...
    802 bytes (66 words) - 01:29, 16 July 2024
  • Thumbnail for Glucose
    (fluorescence-labeled) enzymes as reporters. Glucose can be quantified by copper iodometry. In particular, for the analysis of complex mixtures containing glucose...
    121 KB (12,789 words) - 20:47, 6 September 2024
  • Redox titration Titrant Iodometry Iodine (I2) Bromatometry Bromine (Br2) Cerimetry Cerium(IV) salts Permanganometry Potassium permanganate Dichrometry...
    2 KB (231 words) - 14:13, 17 April 2024
  • Thumbnail for Iodine monobromide
    room temperature. Like iodine monochloride, IBr is used in some types of iodometry. It serves as a source of I+. Its Lewis acid properties are compared with...
    3 KB (187 words) - 04:29, 28 December 2023
  • Thumbnail for Thiosulfate
    tetrathionate ions: 2 S2O2−3 + I2 → S4O2−6 + 2 I− This reaction is key for iodometry. With bromine (X = Br) and chlorine (X = Cl), thiosulfate ions are oxidized...
    12 KB (1,269 words) - 04:58, 4 September 2024
  • Thumbnail for Chemistry of ascorbic acid
    oxidizing agent, and several procedures have been developed. The popular iodometry approach uses iodine in the presence of a starch indicator. Iodine is...
    24 KB (2,359 words) - 23:02, 28 September 2024
  • Thumbnail for Iodine
    anions are often used for quantitative volumetric analysis, for example in iodometry. Iodine and starch form a blue complex, and this reaction is often used...
    107 KB (11,980 words) - 14:44, 28 September 2024
  • Thumbnail for Triiodide
    Tribromide Polyhalogen ions Three-center four-electron bond Iodine–starch test Iodometry Povidone-iodine Lugol's iodine Dye-sensitized solar cell Organic superconductor...
    16 KB (1,587 words) - 01:35, 9 March 2024
  • paints. The determination of iodine value is a particular example of iodometry. A solution of iodine I2 is yellow/brown in color. When this is added...
    25 KB (2,513 words) - 20:38, 19 September 2024
  • Thumbnail for Titration
    of the color of the excess oxidizing agent potassium permanganate. In iodometry, at sufficiently large concentrations, the disappearance of the deep red-brown...
    40 KB (4,672 words) - 15:08, 22 September 2024
  • quantitatively, the bromine consumed by a sample can be determined by iodometry. The bromine number indicates the degree of unsaturation of a sample....
    2 KB (325 words) - 19:09, 1 June 2023
  • Thumbnail for Mixing (process engineering)
    cylindrical stir bar can be used for suspension of solids, as seen in iodometry, deagglomeration (useful for preparation of microbiology growth medium...
    38 KB (4,890 words) - 14:40, 17 July 2024
  • Thumbnail for Polythionates
    obtained by oxidation of thiosulfate ion with iodine (reaction is used in iodometry): S2O2−3 + I2 → S4O2−6 + 2 I− More specialized routes involve reactions...
    2 KB (273 words) - 04:29, 28 December 2023
  • oxidation states suitable for cerimetry is determined in one titration. Iodometry Redox titration Nonstoichiometry Redox indicator Oxidizing agent Reducing...
    4 KB (435 words) - 17:29, 21 February 2021
  • Tutundžić gave original pioneering contributions to the development of iodometry, metalometry, permanganometry, bichromatometry, indirect coulometric titration...
    6 KB (615 words) - 07:12, 24 August 2024